Megatron LIFTX
LIFTX Lift Station Monitor
Cloud-Based Alarming, Monitoring, and Reporting of Lift Station Conditions via WebAdvantage.
Description
Application
MegaTron LIFTX monitors provide web-based alarming and reporting of remote lift station conditions, such as: high-level switch, pressure, temperature, motor current draw, generator switch over, loss of power, security, and more, with WebAdvantage cloud-based remote alarming and reporting.
Units come complete with the first 12 months of cellular service for easy start-up and web connectivity.
WebAdvantage provides web-based access of settings, conditions, e-mail alarming to multiple users and unique custom reporting.
Key Features
- Built-In Cellular Connection
- Remote Alarms, Alerts, & Status
- Customizable Info/Naming
- 5 or 10 Digital Inputs
- Optional Totalizing Flow Inputs
- Up to 8 mA Inputs
- Up to 4 mA Outputs
- Customizable Notepad
- WebAdvantage Reporting
Build a Model
The model number stars with LIftx follwed by the desired options (Example: LIFTX-N4)
Base units include:
- 5 digital inputs, a builtin cell router, and 12 months of data.
- 10 customizable notepad fields for manual reading test entry. These entries can generate alarms and are stored historically for graphing and reporting.
- conduit connections for incoming power.
All required sensors must be sourced separately.
Options:
| A24 | 24 VDC power supply for mA inputs |
| D | Blue poly mounting panel 18”T x 20”W |
| L | (5) additional digital alarm inputs |
| M | Remote mag mount antenna, adds ON/OFF switch |
| N4 | (4) 4-20mA isolated inputs |
| N8 | (8) 4-20mA isolated inputs (O4 is not available with the N8 option) |
| O4 | (4) 4-20mA isolated outputs |
| R | Adds 5 control relays, 120 VAC with pigtails plus an ON/OFF switch on the side of the unit, and mounts cell router in external enclosure |
| S | Delayed cell service start |
| S1 | AT&T™ service instead of Verizon™ (no delay) |
| S2 | Cell router only, with no 12 months of data or SIM card |
| W4 | (4) totalizing flow meter inputs with volume tracking and alarming |
Additional information
| Weight | 10 kg |
|---|
| Electrical Input: | 95-240 VAC, 50/60 Hz |
| Relay Outputs: | Dry contact relays pass through current is limited to 2.5mA at 28 VDC. |
| Display: | 240 X 128 Graphic LCD |
| Digital Inputs: | From open collector/open drain output or a dry contact. Inputs have 10K Ω pullup to 3.3 VDC. |
| Flow Totalizing Inputs: | From open collector/open drain output or dry contact. Inputs use 10K Ω pullup to 5 VDC with a max input rate of 2.5 KHz. |
| mA Inputs: | Optical isolation, 250 Ω / 5 VDC @ 20 mA. Loop voltage to not exceed 30 VDC. |
| mA Outputs: | With non-isolated 12 VDC power from unit max load = 400 Ω. With isolated external 24 VDC power supply, max load = 800 Ω. |
| Enclosure: | Heavy duty NEMA 4X style high impact ABS with padlockable, gasketed Lexan cover |
| Ambient temperature: | 0° to 125°F (-17° to 52°C) |
| Relative humidity: | 0 to 100% |
| Shipping Weight: | Approximately 8 lbs. (4.99 kg) |
| Mounting Dimenstions: | 7.5″ (191 mm) x 10″ (254 mm) |
| Overal Dimensions: | 8.94″ (227 mm) x 11.25″ (286 mm) |